6500 – GC

With improved APCs (Advanced Pneumatic Control), YL’s 5th-generation Gas chromatograph provides fast, reliable and precise data from every single part — from stable inlets to detectors — as well as the from innovative haptic touch pad, which makes the instrument more intuitive and easier to operate while expediting the data-processing cycle. Furthermore, the GC can be configured to perform complex analyses with the installation of inlet and detector components.

Download Brochure
Categories: ,

Specifications

Usable volume
14 L
Temperature operating range
4 °C above ambient to 450 °C or more
Cooling down option
- 80 °C ~ 450 °C (with LN2 cryogenic cooling)
- 40 °C ~ 450 °C (with LCO2 cryogenic cooling)
Temperature set-point
0.1 °C
Temperature programming
25 ramps/26 plateaus
Maximum heating rate
120 °C/min
Maximum run time
9,999 min
Temperature program method
Maximum up to 20
Temperature stability
±0.01 °C (Isothermal), ±0.1 °C (Gradient)

Features

View

  • Enlarged haptic color LCD (5.7″”) showing all factors at a glance
  • Classic and lab-suitable design
  • Intuitive and user-friendly view by YL chromatography data system

Verification

  • High speed data process by network (LAN) communication
  • Enhanced APCs for all modules
  • Upgraded column oven
  • Programming ramp/plateaus : 25/26
  • Temperature Stability : ± 0.01 ℃

Value

  • Saving user’s valuable time with a high throughput autosampler
  • Improved column conditioning function
  • Automatic set of split flow up to 5 ml/min on column conditioning
  • Sensitive leak detection (H2)
  • Prevention of oven malfunction (Over heating)
  • Automatic stop when an oven door gets opened during operation

Variety

  • Maximum no.of inlet / detector installation : 3
  • Various inlets available : Capillary(Split/Splitless) / Packed / On-column inlet
  • Various detectors with high sensitivity available
    1. Flame ionization detector (FID): MDL < 1.5 pg C/sec
    2. Thermal conductivity detector (TCD): MDL < 2.5 ng /ml
    3. Micro-thermal conductivity detector (µTCD): MDL < 400 pg/ml
    4. Nitrogen phosphorus detector (NPD):MDL < 0.2 pg N/sec, <0.02 pg P/sec
    5. Flame photometric detector (FPD) : 1.0 pg S/sec, 0.2 pg P/sec
    6. Electron capture detector (ECD) : MDL < 10 fg/sec
    7. Pulsed discharge detector (PDD)
    8. Pulsed flame photometric detector (PFPD)
    9. Mass Spectrometer(MS)

Maintenance Videos

Capillary Column Installation in the Inlet

Liner & O-ring Replacement for Capillary Inlet

Septum Replacement for Capillary Inlet